Hi
I have two ones and one of these feels strange when on even if it's not playing music. When you touch it there is a slight vibrating/static feeling which is hard to describe. The other device does not have this feeling at all. The strange feeling isn't accompanied by any strange noise just the feeling. Any ideas what could cause this?
    This topic has been closed for further comments. You can use the search bar to find a similar topic, or create a new one by clicking Create Topic at the top of the page.

    23 replies

    Lyricist I
    May 10, 2019 9:57 AM UTC
    I've had such a situation in my old house. The metal cabinet of my stereo receiver also gave a kind of vibration as I touched it. When I put a voltage tester against the cabinet, the lamp would light up. An electrician said that there had to be something wrong with the electric wiring in the house. It can however take some time to research the problem. I never had it solved, just lived with it. In my new house this problem didn't occur.
    Translate
    passopp
    May 10, 2019 10:47 AM UTC
    Typical symptoms of a grounding issue. Could be a broken ground contact on the plug itself or the entire circuit is affected but then all of the plugs connected to said circuit would show the same symptoms.
    Translate
    BigskullAuthor
    Enthusiast I
    May 10, 2019 12:19 PM UTC
    There's an article on the Dell website about similar issues in laptops. This is said to be due to the use of a two pronged power cable instead of three. Apparently it's nothing to be concerned about. Could this be the same cause with the One?
    Can anyone else feel this, particularly on the smooth bit on the back of the One?
    Translate
    May 10, 2019 12:29 PM UTC
    All my Sonos units have a two pronged cable with similar sockets. I don't get any tingle at all. But I remember getting it off the body edges of my MacBook at times. I don't think this is a big issue.
    Translate
    bockersjv
    Local Superstar
    May 10, 2019 12:35 PM UTC
    If you are in the UK get one of these
    https://www.amazon.co.uk/KKmoon-Automatic-Electric-Neutral-Testing/dp/B01FDI6NWM/ref=sr_1_5?crid=5II7JINVLTKZ&keywords=uk+socket+tester&qid=1557491439&s=gateway&sprefix=uk+socket%2Caps%2C148&sr=8-5

    They are only cheap and useful for checking all sockets in the house. 3 of mine had live/neutral round the wrong way.

    The Play one does not have an earth lead only the two pin figure of 8 lead which can be connected either way so polarity should not be an issue. I have had numerous items showing these signs, things like synthesisers, record decks etc.

    John
    Translate
    May 10, 2019 12:39 PM UTC
    3 of mine had live/neutral round the wrong way.

    That must be it; but does it matter to equipment or human safety if left unaddressed?
    Translate
    May 10, 2019 12:45 PM UTC
    Some research clarified why this is dangerous to people for things like toasters; but I am not sure there is any risk to the equipment itself. Using Sonos is probably ok, therefore, but the risk of other uses in future for the socket suggests that it is better to fix it.
    Translate
    buzz
    Grand Maestro
    May 10, 2019 1:42 PM UTC
    Humans are somewhat sensitive to this leakage and sensitivity varies from individual to individual, with moisture level in the skin, and pressure of the "touch".

    Typically, electronics equipment is tested for leakage as part of the manufacturing process. Naturally, failures can occur along the way. These can be component failure, mechanical failure or introduction of a liquid. In terms of feeling the tingle, this is tied to the voltage, which is usually tied to the local mains voltage. If current is limited, there is no danger for the human. A circuit tester or voltmeter might indicate full mains voltage, but these devices don't draw much current and are virtually useless to assess danger to the human. Further, cheap testers might indicate lower voltages than expensive testers because the cheap testers draw more current.

    Sorry, I couldn't find any easy to understand articles to quote.

    Obviously, in this example there is a difference between the outlets. I suspect that there is a wiring fault, but with the information given, we cannot assess risk level to the human. In my experience, some electricians are able to deal with this sort of situation, especially if there is an obvious wiring fault. I have not seen any electricians who are equipped to make leakage measurements. Many electronic service centers are equipped to make these measurements. If the service center has a "HIPOT" tester, they could check the equipment for dangerous leakage.
    Translate
    BigskullAuthor
    Enthusiast I
    May 10, 2019 6:41 PM UTC
    Thanks for all of the replies. Ive done some further investigation and I can actually notice it on both my ones and on all sockets in the house (some which are much newer installations than others). Could there be an earthing issue that effects all the different ring circuits in the house? This is a very slight feeling that is more noticeable if you turn the Sonos off when feeling it. Maybe I need to try a Sonos in someone else's house or maybe I just need to stop rubbing the back of my speakers.
    Translate
    BigskullAuthor
    Enthusiast I
    May 10, 2019 6:43 PM UTC
    This isn't noticeable on any other electricals I have. Yes, I'm going around the house feeling everything now.