I am curious if SONOS thought about how they expect the Playbar to be wall mounted with the wiring concealed. From the looks of it, and the optional wall bracket, they did not think to hard. :)

Surely they are aware that if you wish to adhere to electrical codes, you cannot simply run the power cord through the wall. It needs to have an outlet behind the speaker. That is the main concern. And it applies to nearly all soundbars that are powered via high voltage.

As a custom installer, I will find a way to do it. I have 2 ideas in mind and will post an update when I have figured it out. But manufacturers need to take some thought about how people are going to use their products and design them accordingly.

Stay tuned for "how to mount your playbar, conceal the wiring, and keep it legal". 🙂
This topic has been closed for further comments. You can use the search bar to find a similar topic, or create a new one by clicking Create Topic at the top of the page.

33 replies

Stanley_4
Grand Maestro
July 22, 2018
waynecram, that first link is interesting but it is going to require you use their other bits to complete the system or possibly start opening the case and cutting wires, not something I'd recommend. The full setup would be great though.

The screw assortment may be overkill, Ace, Home Depot or Lowe's will have a selection of spacers and longer "into the wall" screws which you may want too.
Lyricist I
July 22, 2018
Yeah, the second link was useless. Just there to show spacers, really. I think the whole kit from powerbridge might do the trick to hide everything. Disappointing that sonos Wall Mount is flush and only offers small opening for wires.
Stanley_4
Grand Maestro
July 23, 2018
I'd have to agree, no reason Sonos couldn't include a set of spacers and if needed longer screws to get it to work over an embedded outlet box.

The PowerBridge looks interesting but there is one gotcha that is going to make installing it a lot of "fun" in most cases. For sheetrock/drywall construction there are usually short pieces of wall stud placed horizontally at the four foot sheet boundaries, both to help hang the sheets and as a bit of a fire-stop. You will have to drill a hole large enough for the connector to pass through and hold the cable and any other connections between units in that piece of stud. A rental hole-saw with a flex shaft is the usual answer.

Doing your own setup without the custom plugs will let you use smaller, maybe only 1/2 inch, holes that can sometimes be made with just a long drill bit or an extension since you are just passing a single run of Romex AC wire and your cables instead of that bigger plug.