I’m trying to fix a “no power” Connect:Amp Gen 2 and made great progress - before it all went wrong.
Fix: Fuse was blown and two MOVs on the VPRI/VMID rails were low resistance. I replaced these, reassembled enough to test it, and it booted! The app found it, added it to a room, and then said it needed an update. This went ahead but the unit didn’t come back afterwards.
Current: It powers up (3.3V and 5V rails fine), turns on the white LED for 4 seconds, this then goes off for 18 seconds, and then it repeats. While the LED is off, the Ethernet lights are flashing as expected, so I guess MAC and PHY have been initialised. It will not go into factory reset mode by holding play/pause when powering up.
Theories: 1) it was bricked during the update and I’m screwed, 2) there is a fault elsewhere that the previous firmware didn’t detect but this firmware does.
I see chat elsewhere about 36V to the riser board, but my reading of the PCB is that the riser just enables the MOSFETS to supply DC to the rest of the 36V supply. My next play is to check the MOSFETs (drive, input, output) but if the bare truth is that theory 1 is correct then I’m wasting my time.